My Shopping Cart
MB BGA Tool VVDI2 2017 Launch X431 XTruck USB Link VXDIAG VCX NANO Volvo VCADS Launch X431 V XTUNER X100 Pad CBAY Handy Baby
Home
Home - Products - OBD2 Cable and Connector - OBD II Vehicle ECU Emergency Power Supply Cable Memory Saver(3Meter)
« Go Back
46
OBD II Vehicle ECU Emergency Power Supply Cable Memory Saver(3Meter)

OBD II Vehicle ECU Emergency Power Supply Cable Memory Saver(3Meter)

Item No. SF204
0 stars, 0 reviews.
In Stock
Latest price:$12.99 Buy It Now:$6.99
You save $6.00 46% off
Quantity:
    
Shipping:
Free Shipping     Standard Flat Rate Shipping Service 
Estimated delivery time: 7-18 working days.See details »
Weight:
0.2KG        ( 0.44LB )
Package:
19cm*15cm*2cm        ( Inch: 7.48*5.91*0.79 )
Returns:
Return for refund within 7 days,buyer pays return shipping.Read details »
Buy more related tools and Save more!
EIS/ELV Test Line for Mercedes Works Together with VVDI BGA
(Item No. SF205)
EIS/ELV Test Line for Mercedes
No need have car for test
Can works together with VVDI BGA    More Details »
 Free Shipping
Buy It Now:$119.00
Quantity:   
Add to Cart
USB Cable for Volvo 88890305 Vocom
(Item No. SF203)
USB Cable for Volvo 88890305 Vocom    More Details »
 Free Shipping
Buy It Now:$52.99
Quantity:   
Add to Cart
Replacing a car battery on older vehicles used to be simple!! You unhook the old battery and install the new one. Late-model vehicles, however, rely on computers that operate everything from the stereo to the transmission. If power is disconnect from ecu, the settings will lost and have to reset to default. That means the vehicle may feel different when driven, and you may have to enter a security code to access the stereo. Using this simple memory saving device when replacing your car battery will help you avoid these problems.

OBD II Vehicle ECU Emergency Power Supply Cable Memory Saver(3Meter)

Product Description and Operation: 


1. Powered by any jump starter with a 12V outlet into an OBD II Memory Saver. 
2. Interface connector between a 12V DC power source and vehicle's OBD II port. 
3. Preserves vehicle codes and electronic presets. 

This device can work with any 12V DC power source, including jump starter, DC 12V Lead-acid battery, or another car’s DC 12V power outlet.
As our device with 3 meter cable, it will be a convenient way, should you not have jump starter (or Lead-acid  battery)  on hand, and the device can also get the 12v power supply from cigarette lighter of another good car. Just insert the Cigarette lighter plug to this car and insert into 16 pin plug to the OBD port of the car you want to replace battery. And now you can replace the battery.
 
Warning: 

1. When working with the vehicle’s battery, review all the battery manufacturer’s and vehicle manufacturer’s safety instructions, warnings and directives regarding  battery disconnection, removal and replacement. 
2. The vehicle’s electrical system is receiving power from memory saver through the OBD connection. Therefore, the vehicle’s battery connectors are electrically live and should be covered with an insulator to  prevent the connectors from touching metal or each other and causing a short circuit. After each use, disconnect the memory saver  and use a dry cloth to wipe all dirt or oil from the connectors and the cable. 
3. During battery replacement, DO NOT turn on (ignition) the car, which its old battery  is disconnected and new battery not yet finished replacement. As well, DO NOT  turn the key on “ACC ON”. If not, the fuse of the memory saver probably burn out, due to high amp and overload. 
4. Security attach the OBD II connector of memory saver into your car OBD II port to get a good contact; if not, during battery replacement.  the bad  contact between  the OBDII connector and your car, may cause missing power supply on your car ECU (Electronic Control Unit, or called auto computer). 

Troubleshooting:

1. The 12V DC plug of memory saver should be correctly connected 12V power source, if not, the red led light on the plug will not light up; 
    that means no power signal from the power source or with incorrect polarity connection. If the power source from another car, 
    then check whether the car’s Cigarette Lighter on good condition or not. If the power source from a jump starter, then verify if the cause is 
    from the contact. If the power source is from an alternative 12V Lead-acid battery, then check whether the polarity correct or not. 
2.The memory saver 12V DC plug contains an 8 amp fuel. Should a problem arise with the memory saver, check the fuse or contact your direct seller/distributor for assistance. 

Package Including:

1pc x  OBD II Automotive Computer Memory Saver(3m)

 
Scan UOBDII QR code to order anywhere and anytime by mobile phone
UOBDII QR Code
Contact Information:

Whatsapp: +86-13995696053
Live Support: Chat with us online
Email: sales@uobdii.com
Skype: uobd2net@live.com
If you have any problem, please do not hesitate to contact us.

Shipment Note:

If your package shipped by Express Delivery, please give us a valid delivery phone number, and also a full and accurate shipping address.

How to Buy from UOBD2?

how to buy one UOBDII.com

 
Shipment & Payment
Return Information
Customer Service
Join Our Community
UOBD2 facebookUOBD2 twitteruobd2 google plusuobd2 youtube
UOBD2 LinkedinUOBD2 blogUOBD2 RSSuobd2 Pinterest
Newsletter get Coupon: